Representation of an optimal power flow result.
"""
import logging
import numpy as np
from hynet.types_ import SolverType, SolverStatus
from hynet.system.result import SystemResult
import hynet.config as config
_log = logging.getLogger(__name__)
[docs]class OPFResult(SystemResult):
"""
Result of an optimal power flow calculation.
**Remark:** In the data frames below, the respective column for the dual
variables of a type of constraint (e.g., voltage drop) is only present if
at least one constraint of this constraint type appears in the problem
formulation.
Parameters
----------
model : OPFModel
Model for the processed optimal power flow problem.
empty : bool
``True`` if the object does not contain any result data and ``False``
otherwise.
solver : SolverInterface
Solver object by which the result was obtained.
solver_status : SolverStatus
Status reported by the solver.
solver_time : float
Duration of the call to the solver in seconds.
optimal_value : float
Optimal objective value or ``numpy.nan`` if the solver failed.
total_time : float or numpy.nan
Total time for the OPF calculation, including the modeling, solving,
and result assembly. If not provided, this time is set to ``numpy.nan``.
reconstruction_mse : float
Unavailable if the result is empty and, otherwise, the mean squared
error of the reconstructed bus voltages in case of a relaxation and
``numpy.nan`` otherwise.
bus : pandas.DataFrame, optional
Unavailable if the result is empty and, otherwise, a data frame with
the bus result data, indexed by the *bus ID*, which comprises the
following columns:
``v``: (``hynet_complex_``)
Bus voltage rms phasor (AC) or bus voltage magnitude (DC).
``s_shunt``: (``hynet_complex_``)
Shunt apparent power in MVA. The real part constitutes the shunt
losses in MW and the *negated* imaginary part constitutes the
reactive power *injection*.
``bal_err``: (``hynet_complex_``)
Power balance residual in MVA, i.e., the evaluation of the
complex-valued power balance equation at the system state.
Theoretically, this should be identical to zero, but due to a
limited solver accuracy and/or inexactness of the relaxation it is
only approximately zero. This residual supports the assessment of
solution accuracy and validity.
``dv_bal_p``: (``hynet_float_``)
Dual variable or KKT multiplier of the active power balance
constraint in $/MW. In case of exactness of the relaxation (or
zero duality gap in the QCQP), these dual variables equal the
locational marginal prices (LMPs) for active power, cf. [1]_.
``dv_bal_q``: (``hynet_float_``)
Dual variable or KKT multiplier of the reactive power balance
constraint in $/Mvar. In case of exactness of the relaxation (or
zero duality gap in the QCQP), these dual variables equal the
locational marginal prices (LMPs) for reactive power, cf. [1]_.
``dv_v_min``: (``hynet_float_``)
Dual variable or KKT multiplier of the voltage lower bound in $/p.u..
``dv_v_max``: (``hynet_float_``)
Dual variable or KKT multiplier of the voltage upper bound in $/p.u..
branch : pandas.DataFrame, optional
Unavailable if the result is empty and, otherwise, a data frame with
the branch result data, indexed by the *branch ID*, which comprises the
following columns:
``s_src``: (``hynet_complex_``)
Apparent power flow in MVA at the source bus (measured as a flow
*into* the branch).
``s_dst``: (``hynet_complex_``)
Apparent power flow in MVA at the destination bus (measured as a
flow *into* the branch).
``i_src``: (``hynet_complex_``)
Current flow in p.u. at the source bus (measured as a flow
*into* the branch).
``i_dst``: (``hynet_complex_``)
Current flow in p.u. at the destination bus (measured as a flow
*into* the branch).
``v_drop``: (``hynet_float_``)
Relative voltage magnitude drop from the source bus to the
destination bus.
``angle_diff``: (``hynet_float_``)
Bus voltage angle difference in degrees between the source and
destination bus.
``effective_rating``: (``hynet_float_``)
Ampacity in terms of a long-term MVA rating at the *actual* bus
voltage. If no rating is available, it is set to ``numpy.nan``.
``rel_err``: (``hynet_float_``)
Branch-related relative reconstruction error
:math:`\\kappa_k(V^\\star)` as defined in equation (24) in [1]_ in
case of a relaxed OPF or ``numpy.nan`` otherwise.
``dv_i_max_src``: (``hynet_float_``)
Dual variable or KKT multiplier of the ampacity constraint at the
source bus in $/p.u. or ``numpy.nan`` if unavailable.
``dv_i_max_dst``: (``hynet_float_``)
Dual variable or KKT multiplier of the ampacity constraint at the
destination bus in $/p.u. or ``numpy.nan`` if unavailable.
``dv_angle_min``: (``hynet_float_``)
Dual variable or KKT multiplier of the angle difference lower bound
constraint or ``numpy.nan`` if unavailable.
``dv_angle_max``: (``hynet_float_``)
Dual variable or KKT multiplier of the angle difference upper bound
constraint or ``numpy.nan`` if unavailable.
``dv_real_part``: (``hynet_float_``)
Dual variable or KKT multiplier of the +/-90 degrees constraint
on the angle difference (cf. equation (27) in [2]_) or
``numpy.nan`` if unavailable.
``dv_drop_min``: (``hynet_float_``)
Dual variable or KKT multiplier of the voltage drop lower bound
constraint or ``numpy.nan`` if unavailable.
``dv_drop_max``: (``hynet_float_``)
Dual variable or KKT multiplier of the voltage drop upper bound
constraint or ``numpy.nan`` if unavailable.
converter : pandas.DataFrame
Unavailable if the result is empty and, otherwise, a data frame with
the converter result data, indexed by the *converter ID*, which
comprises the following columns:
``p_src``: (``hynet_complex_``)
Active power flow in MW at the source bus *into the converter*.
``p_dst``: (``hynet_complex_``)
Active power flow in MW at the destination bus *into the
converter*.
``q_src``: (``hynet_complex_``)
Reactive power injection in Mvar at the source bus *into the grid*.
``q_dst``: (``hynet_complex_``)
Reactive power injection in Mvar at the destination bus *into the
grid*.
``loss_err``: (``hynet_float_``)
Loss error in MW due to noncomplementary modes of the converter.
``loss_err_pre``: (``hynet_float_``)
Only available if the OPF QCQP was pre-solved to detect and fix the
converter modes. Loss error in MW in the pre-solution due to
noncomplementary modes of the converter.
``dv_p_fwd_min``: (``hynet_float_``)
Dual variable or KKT multiplier of the lower bound on the
converter's forward mode active power flow in $/MW or ``numpy.nan``
if unavailable.
``dv_p_fwd_max``: (``hynet_float_``)
Dual variable or KKT multiplier of the upper bound on the
converter's forward mode active power flow in $/MW or ``numpy.nan``
if unavailable.
``dv_p_bwd_min``: (``hynet_float_``)
Dual variable or KKT multiplier of the lower bound on the
converter's backward mode active power flow in $/MW or ``numpy.nan``
if unavailable.
``dv_p_bwd_max``: (``hynet_float_``)
Dual variable or KKT multiplier of the upper bound on the
converter's backward mode active power flow in $/MW or ``numpy.nan``
if unavailable.
``dv_cap_src_q_min``: (``hynet_float_``)
Dual variable or KKT multiplier of the reactive power lower bound
of the capability region at the source bus in $/Mvar or
``numpy.nan`` if unavailable.
``dv_cap_src_q_max``: (``hynet_float_``)
Dual variable or KKT multiplier of the reactive power upper bound
of the capability region at the source bus in $/Mvar or
``numpy.nan`` if unavailable.
``dv_cap_dst_q_min``: (``hynet_float_``)
Dual variable or KKT multiplier of the reactive power lower bound
of the capability region at the destination bus in $/Mvar or
``numpy.nan`` if unavailable.
``dv_cap_dst_q_max``: (``hynet_float_``)
Dual variable or KKT multiplier of the reactive power upper bound
of the capability region at the destination bus in $/Mvar or
``numpy.nan`` if unavailable.
``dv_cap_src_lt``: (``hynet_float_``)
Dual variable or KKT multiplier of the left-top half-space of
of the capability region at the source bus in $/MVA or
``numpy.nan`` if unavailable.
``dv_cap_src_rt``: (``hynet_float_``)
Dual variable or KKT multiplier of the right-top half-space of
of the capability region at the source bus in $/MVA or
``numpy.nan`` if unavailable.
``dv_cap_src_lb``: (``hynet_float_``)
Dual variable or KKT multiplier of the left-bottom half-space of
of the capability region at the source bus in $/MVA or
``numpy.nan`` if unavailable.
``dv_cap_src_rb``: (``hynet_float_``)
Dual variable or KKT multiplier of the right-bottom half-space of
of the capability region at the source bus in $/MVA or
``numpy.nan`` if unavailable.
``dv_cap_dst_lt``: (``hynet_float_``)
Dual variable or KKT multiplier of the left-top half-space of
of the capability region at the destination bus in $/MVA or
``numpy.nan`` if unavailable.
``dv_cap_dst_rt``: (``hynet_float_``)
Dual variable or KKT multiplier of the right-top half-space of
of the capability region at the destination bus in $/MVA or
``numpy.nan`` if unavailable.
``dv_cap_dst_lb``: (``hynet_float_``)
Dual variable or KKT multiplier of the left-bottom half-space of
of the capability region at the destination bus in $/MVA or
``numpy.nan`` if unavailable.
``dv_cap_dst_rb``: (``hynet_float_``)
Dual variable or KKT multiplier of the right-bottom half-space of
of the capability region at the destination bus in $/MVA or
``numpy.nan`` if unavailable.
injector : pandas.DataFrame
Unavailable if the result is empty and, otherwise, a data frame with
the injector result data, indexed by the *injector ID*, which comprises
the following columns:
``s``: (``hynet_complex_``)
Apparent power injection in MVA.
``cost_p``: (``hynet_float_``)
Cost of the active power injection in dollars or ``numpy.nan`` if
no cost function was provided.
``cost_q``: (``hynet_float_``)
Cost of the reactive power injection in dollars or ``numpy.nan`` if
no cost function was provided.
``dv_cap_p_min``: (``hynet_float_``)
Dual variable or KKT multiplier of the active power lower bound
of the capability region in $/MW or ``numpy.nan`` if unavailable.
``dv_cap_q_min``: (``hynet_float_``)
Dual variable or KKT multiplier of the reactive power lower bound
of the capability region in $/Mvar or ``numpy.nan`` if unavailable.
``dv_cap_p_max``: (``hynet_float_``)
Dual variable or KKT multiplier of the active power upper bound
of the capability region in $/MW or ``numpy.nan`` if unavailable.
``dv_cap_q_max``: (``hynet_float_``)
Dual variable or KKT multiplier of the reactive power upper bound
of the capability region in $/Mvar or ``numpy.nan`` if unavailable.
``dv_cap_lt``: (``hynet_float_``)
Dual variable or KKT multiplier of the left-top half-space of
the capability region in $/MVA or ``numpy.nan`` if unavailable.
``dv_cap_rt``: (``hynet_float_``)
Dual variable or KKT multiplier of the right-top half-space of
the capability region in $/MVA or ``numpy.nan`` if unavailable.
``dv_cap_lb``: (``hynet_float_``)
Dual variable or KKT multiplier of the left-bottom half-space of
the capability region in $/MVA or ``numpy.nan`` if unavailable.
``dv_cap_rb``: (``hynet_float_``)
Dual variable or KKT multiplier of the right-bottom half-space of
the capability region in $/MVA or ``numpy.nan`` if unavailable.
References
----------
.. [1] M. Hotz and W. Utschick, "The Hybrid Transmission Grid Architecture:
Benefits in Nodal Pricing," in IEEE Trans. Power Systems, vol. 33,
no. 2, pp. 1431-1442, Mar. 2018.
.. [2] M. Hotz and W. Utschick, "A Hybrid Transmission Grid Architecture
Enabling Efficient Optimal Power Flow," in IEEE Trans. Power
Systems, vol. 31, no. 6, pp. 4504-4516, Nov. 2016.
"""
def __init__(self, model, qcqp_result, total_time=np.nan, qcqp_result_pre=None):
"""
Create an OPF result object.
Parameters
----------
model : hynet.opf.model.OPFModel
Model for the processed OPF problem.
qcqp_result : hynet.qcqp.result.QCQPResult
Solution of the OPF QCQP.
total_time : .hynet_float_, optional
Total time for solving the OPF.
qcqp_result_pre : QCQPResult, optional
Pre-solution of the OPF QCQP for converter mode detection.
"""
super().__init__(model,
qcqp_result,
total_time=total_time,
qcqp_result_pre=qcqp_result_pre)
self._result_title = 'Optimal Power Flow'
self._unit_dv_bal_p = '$/MWh'
self._unit_dv_bal_q = '$/Mvarh'
def __repr__(self):
"""Return a summary of the result."""
t = ""
t += self._get_header()
t += "|> Data Source " + "-"*63 + "<|\n"
t += "|" + " "*78 + "|\n"
t += self._get_data_source_summary()
t += "|" + " "*78 + "|\n"
t += "|> Grid Information " + "-"*58 + "<|\n"
t += "|" + " "*78 + "|\n"
t += self._get_grid_structure_summary()
t += "|" + " "*78 + "|\n"
t += self._get_grid_injection_summary()
t += "|" + " "*78 + "|\n"
if not self.empty:
t += "|> Results " + "-"*67 + "<|\n"
t += "|" + " "*78 + "|\n"
t += self._get_injection_and_loss_summary()
t += "| Loss price:{:12.3f} $/MWh{:>13s}Loss penalty:{:14.3f} k$/h{:>4s}\n"\
.format(self.scenario.loss_price,
"| ",
self.get_dynamic_losses() * self.scenario.loss_price / 1e3,
"|")
t += "|" + " "*40 + "-+----+-" + " "*30 + "|\n"
t += self._get_nodal_and_utilization_summary()
t += "|" + " "*78 + "|\n"
t += "|> Solution Process " + "-"*58 + "<|\n"
t += "|" + " "*78 + "|\n"
t += self._get_solver_info()
t += self._get_solution_accuracy_info()
t += self._get_pathological_price_profile_info()
t += "+" + "-"*78 + "+\n"
return t
def _get_pathological_price_profile_info(self):
t = ""
if not (self.scenario.verify_hybrid_architecture_conditions(log=None) and
self.solver_status == SolverStatus.SOLVED and
self.solver.type != SolverType.QCQP and
not self.has_valid_power_balance and
self.reconstruction_mse >= 1e-8 and
config.OPF['pathological_price_profile_info']):
return t
t += "|" + " "*78 + "|\n"
t += "| This scenario exhibits a pathological price profile. Prominent causes are: |\n"
t += "| (a) Zero marginal cost injectors: This can induce near-zero LMPs for |\n"
t += "| active power. To add loss minimization, see Scenario.loss_price. |\n"
t += "| (b) Shortage of inductive reactive power: This can induce negative LMPs |\n"
t += "| for reactive power. To add compensation, see Scenario.add_compensation. |\n"
t += "| To analyze the cause of inexactness, see hynet.show_power_balance_error. |\n"
t += "| In some cases, Scenario.set_minimum_series_resistance may be supportive. |\n"
return t