[docs]def get_default_initial_point_generator():
"""
Return the default initial point generator for the current system.
If a sufficiently efficient SOCR solver is available, the utilization of a
copper plate based initial point for the solution of the nonconvex QCQP
typically improves the overall performance, i.e., that the reduced number
of iterations of the QCQP solver outweighs the computational cost for the
initial point.
"""
socr_solvers = [x for x in AVAILABLE_SOLVERS if x().type == SolverType.SOCR]
def find_solver(solver_name):
for SolverClass in socr_solvers:
if SolverClass().name == solver_name:
return SolverClass
return None
# Prioritized search for a suitable SOCR solver
for solver_name in ['MOSEK', 'CPLEX']:
SolverClass = find_solver(solver_name)
if SolverClass is not None:
return CopperPlateInitialPointGenerator(SolverClass())
return None
[docs]def calc_opf(data, scenario_id=0, solver=None, solver_type=SolverType.QCQP,
initial_point_generator=get_default_initial_point_generator(),
converter_loss_error_tolerance=5e-4):
"""
Calculate the optimal power flow.
This function formulates and solves the optimal power flow (OPF) problem.
The solver or solver type may be specified explicitly, otherwise an
appropriate solver is selected automatically.
Parameters
----------
data : DBConnection or Scenario or OPFModel
Connection to a *hynet* grid database, a ``Scenario`` object, or a
``OPFModel`` object.
scenario_id : .hynet_id_, optional
Identifier of the scenario. This argument is ignored if ``data`` is a
``Scenario`` or ``OPFModel`` object.
solver : SolverInterface, optional
Solver for the QCQP problem; the default automatically selects an
appropriate solver of the specified solver type.
solver_type : SolverType, optional
Solver type for the automatic solver selection (default
``SolverType.QCQP``). It is ignored if ``solver`` is not ``None``.
initial_point_generator : InitialPointGenerator or None, optional
Initial point generator for QCQP solvers (ignored for relaxation-based
solvers). By default, an appropriate initial point generator is
selected if a computationally efficient SOCR solver is installed.
Set to ``None`` to skip the initial point generation.
converter_loss_error_tolerance : .hynet_float_, optional
Tolerance for the converter loss error in MW (default ``5e-4``). If
``None``, the OPF model's (default) setting is retained.
Returns
-------
result : OPFResult
Optimal power flow solution.
See Also
--------
hynet.scenario.representation.Scenario
hynet.opf.result.OPFResult
hynet.reduction.copper_plate.reduce_to_copper_plate
hynet.opf.initial_point : Initial point generators.
"""
if isinstance(data, OPFModel):
model = data
elif isinstance(data, Scenario):
model = OPFModel(data)
elif isinstance(data, DBConnection):
model = OPFModel(load_scenario(data, scenario_id))
else:
raise ValueError(("The argument 'data' must be DBConnection object, "
"a Scenario object, or an OPFModel object."))
if converter_loss_error_tolerance is not None:
model.converter_loss_error_tolerance = converter_loss_error_tolerance
return calc(model,
solver=solver,
solver_type=solver_type,
initial_point_generator=initial_point_generator)